Machine Down: What to Check First in the First 10 Minutes

Machine down what to check first? Follow a safe, ordered routine: lockout and tagout, a clear symptom, then supply, interlocks, and e-stops.

Open motor terminal box on a stopped conveyor, red lockout padlock on the disconnect, voltage tester and blank notepad on a rubber mat.

Machine down what to check first: the first 10 minutes at a stopped machine

Machine down what to check first is a question with a simple order. Before you take anything apart, isolate the machine with lockout and tagout, confirm exactly what it is doing, and check the simple causes first: supply, interlocks, emergency stops, and anything that changed recently. Write the symptom down in plain words so each check narrows the list instead of starting from zero.

Make the Machine Safe Before You Check Anything

Lockout and tagout comes before any test

Nothing else in this routine matters if someone gets hurt. Before you press a start button to see what happens, or open a panel to look at a contactor, isolate the machine according to your site’s lockout and tagout (LOTO) procedure. That usually means turning off the local disconnect, locking it in the off position, attaching your own tag, and confirming that the machine cannot start from another station or from a timer.

Verify zero energy with a test you trust, not with the assumption that the switch is off. Check that stored energy is released, such as pressurized hydraulic lines, raised loads, or capacitors in drives, and wait for the time your OEM manual specifies before opening enclosures.

Confirm what the machine is actually doing

Operator reports are a starting point, not a finding. “It won’t run” can mean the motor is silent, the display shows a fault, the conveyor starts and stops, or the machine runs but produces no output.

Separate three things: what you observed, what someone told you, and what you inferred. Ask the operator when the machine last ran, what they pressed, and whether anything sounded or looked different. Then, with the machine still locked out, read the display, indicator lights, and any alarm log.

Check the Cheap Causes Before the Expensive Ones

Supply, interlocks, and emergency stops

Start with the checks that take minutes and carry little risk. Confirm that incoming supply is present at the machine, including all phases on three-phase equipment, and that the upstream breaker or fuse has not tripped. Check the local disconnect and any control fuses you can reach safely.

Then look at the stop chain. Guard and door interlocks often hold a machine off even when everything else is healthy: a door switch that has drifted, a guard that is not fully closed, or a light curtain that is blocked. Check every emergency stop on the line, not just the one nearest you, and confirm that each one has been reset. Finally, look at the start command. Is the pushbutton, selector, or controller input showing the signal the machine expects?

Work in this order: supply, fuses and breakers, interlocks, emergency stops, then the start signal.

Look for what changed on the last shift

Sudden faults often follow a recent change, so check what changed. Ask what changed since the machine last ran well: a product or recipe change, a setpoint edit, maintenance done overnight, a new operator, cleaning, lubrication, or a part swapped in. Check for setpoints entered in the wrong unit and for guards left open after cleaning.

Write each change in a list with the time it happened. Then decide which changes could plausibly affect the symptom. A change that touches the same circuit or function as the fault moves to the top. For checks specific to motors and drives, use motor and drive fault troubleshooting, check by check instead of repeating them here.

Write the Symptom Down Before You Start Guessing

Describe what you see, hear, and read

A written symptom is the input that makes every later check useful. Write it in plain words, the way you would explain it to a colleague. Cover five things: what the machine does, what it does not do, when it happens, what the display shows, and what you hear or smell.

For example: “Motor hums for about two seconds at start, then goes quiet. No rotation. No alarm on display. Started after this morning’s product change. Not hot.” That is far more useful than “motor broken.” Timing matters. A fault at start belongs to a different group than one under load or after warm-up. Record fault codes exactly as shown, including numbers, because a code often narrows the list before you run a single check.

Turn each check result into a narrower list

Treat each check as a question with two possible answers. If a check passes, the cause it tests is confirmed or removed. If it fails, that cause moves up. Either way, the next step should change because of the result, not restart from the top.

Keep a short working list: candidate causes at the top, each paired with the check that tests it. After every result, update the list and pick the next check from the top of the revised list. Do not keep running checks in the original order once a result has changed what is likely.

Know When to Stop Checking and Escalate

Faults that fall outside common families

Stop and escalate when the fault has no clear cause after basic checks, when it trips repeatedly with nothing obvious, when you see signs of damage such as scorching, leaks, cracked housings, or a burning smell, when the controls are unfamiliar to you, or when two checks give contradictory results. These signs point to a more experienced technician, the equipment manufacturer, or a planned outage. Stop before any task that requires the machine energized if you are not qualified for it.

Where a structured tool and the manual fit

The OEM manual is the authority for your machine. Torque values, parameter settings, wiring, and safety warnings come from there. A structured tool helps earlier, when you have a symptom and need a short, ordered set of likely causes. For a comparison, see when to use Fault Line AI versus OEM manuals.

Fault Line AI is a web app where you describe the fault in plain words and get a ranked list of likely causes and the next check to run, one step at a time. It fits the step after the basic checks above, and it suggests checks for you to perform. It does not connect to or control your machine, and it does not replace lockout and tagout or the OEM manual. Guided troubleshooting works without signing in, but its results are not saved. To keep a symptom report, you need to sign in and save it. You can try Fault Line AI for plain-language fault diagnosis by describing a fault you are working on right now, with no sign-in needed. If you want a broader view, see a troubleshooting tool for live faults.

Frequently Asked Questions

Should I open a panel or guard before checking the supply and interlocks?

No. Check supply, the upstream breaker, and the interlock and emergency stop states from outside the enclosure first, using the machine’s indicators and your site’s procedure. Open a panel or guard only when a check requires it, and only after lockout and tagout.

What should I write down before I start troubleshooting a stopped machine?

Write what the machine does and does not do, when the fault happens, any display codes exactly as shown, and any sounds or smells. Add the recent changes you know about, with times. A short note like this makes each later check easier to choose.

When should I stop checking on my own and call in a more experienced technician or the OEM?

Stop when the fault has no clear cause after basic checks, trips repeatedly, shows signs of damage, involves controls you do not know, or gives contradictory results. Contact the OEM when the manual does not cover your situation.